The two conductors wires or small bus bars are passed through a sensor.
Dc earth leakage relay schneider.
El731 is an ac dc sensitive earth leakage relay that offers complete coverage for all frequencies with values between 0 and 6.
Earth leakage protection relay vigirex rh10mp rh21mp rh99mp rh197 rhu.
20183 by schneider electric or repair at radwell a9d10806 ic60h earth leakage circuit breaker 1p n circuit breakers electric schneider schneider earth leakage protector ram lachman enterprises schneider rh99p earth.
The measuring method is based on the principle that the positive and the negative current in a fault free load circuit sum to zero.
The dc earth leakage relay includes on board through label healthy and failure leds one per pole and includes a double pole volt free relay rated at 3a 230vac or 30vdc.
Dc earth leakage relay schneider.
Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale.
Thus leakage current if any will be dependent on the resistance value between respective terminals higher the resistance lower is the leakage.
The dc earth leakage relay is capable of detecting earth faults on charger rectifiers and transformer secondary as well as standard dc supplies from batteries or power supplies.
If an earth fault is present the fast response sensor detects the difference between the two currents and.
The dc earth leakage relay is designed to monitor unearthed dc it systems for insulation deterioration or faults.
The relay senses the dc earth leakage current for any equipments like switch boards rectifiers battery chargers by sensing resistance between positive negative terminals of dc system earth.
Thus leakage current if any will be dependent on the resistance value between respective terminals higher the resistance lower is the leakage.
The dc leakage current is measured by electronic ag sensor inserted in each monitored load circuit.
The signals from the sensors are processed by the detector unit and leakage is detected.
The relays can be used in the following ways.
Vigirex relays measure the earth leakage current in an electrical installation via their associated sensors.
The dc earth leakage relay detects leakages from dc power systems by measuring differential current between the ve and ve current carrying conductors.
February 19 2019 hilman rojak leave a comment on dc earth leakage relay schneider.
Ground fault protection rh10 rh21 rh99 with manual reset earth leakage alarming same models plus rh99 with automatic reset ground fault protection.
The ddea that is power supplied from the system to be monitored is connected to earth through an active current limited circuitry trying to keep the earth voltage at half the system voltage.